============================================================================= IGEL Universal Management Suite ============================================================================= Version 6.02.110 Release date: 2019-08-14 HTML version of this Readme is available at: https://kb.igel.com/ums/releasenotes ============================================================================= Supported environment: ============================================================================= UMS Server: Microsoft Windows Server 2008 (64 bit and with SP2) Microsoft Windows Server 2008 R2 (64 bit and with SP1) Microsoft Windows Server 2012 (64 bit) Microsoft Windows Server 2012 R2 (64 bit and with Update 2919355) Microsoft Windows Server 2016 (64 bit) Microsoft Windows Server 2019 (64 bit) Ubuntu 16.04 (64 bit) Ubuntu 18.04 (64 bit) Oracle Linux 7 (64 bit) Red Hat Enterprise Linux (RHEL) 7 (64 bit) UMS Client: Microsoft Windows 7 (64 bit and with SP1 ) Microsoft Windows 8.1 (64 bit and with Update 2919355) Microsoft Windows 10 (64 bit) Microsoft Windows Server 2008 (64 bit and with SP2) Microsoft Windows Server 2008 R2 (64 bit and with SP1) Microsoft Windows Server 2012 (64 bit) Microsoft Windows Server 2012 R2 (64 bit and with Update 2919355) Microsoft Windows Server 2016 (64 bit) Microsoft Windows Server 2019 (64 bit) Ubuntu 16.04 (64 bit) Ubuntu 18.04 (64 bit) Oracle Linux 7 (64 bit) Red Hat Enterprise Linux (RHEL) 7 (64 bit) Backend database (DBMS): Microsoft SQL Server 2012 Microsoft SQL Server 2014 (with Cluster Support) Microsoft SQL Server 2016 (with Cluster Support) Microsoft SQL Server 2017 (with Cluster Support) Oracle 11g R2 Oracle 12c PostgreSQL 9.4 - 9.6 and 10.1 Apache Derby 10 ============================================================================= New features: ============================================================================= [Server, common] - Updated Apache Tomcat from version 8.5.40 to 8.5.43 [IGEL Cloud Gateway (ICG)] - Added: Support for Shadowing via IGEL Cloud Gateway (ICG 2.01.100 or higher and IGEL OS 11.02.100 or higher are required) ============================================================================= Resolved issues: ============================================================================= [AD / LDAP integration] - Fixed: AD authentication was not possible in a mixed domain/sub domain environment. [Thin clients] - Fixed: Firmware update settings of a device shown in UMS differed from the settings the device received when an Universal Firmware Update and a profile with configured firmware update settings were assigned to the device. [Views] - Added: The timeout for the online check of devices that is set in UMS Administration -> Global Configuration ->Server Network Settings -> Online Check Parameters will be used for the Online criterion in Views. [IGEL Cloud Gateway (ICG)] - Changed: Due to structural changes between ICG 1.04 and ICG 2.01 a downgrade is not possible. It is also disabled in the ICG remote installer. - Fixed: Changing the name of an ICG or an UMS Server does no longer result in an error message. [DB command line tools] - Fixed: The embackup command line tool didn't find the backup file in restore mode although it existed. [Server, common] - Fixed: Downloading global notifications (by UMS itself or via the "Send notification information via mail" administrative task) failed with Microsoft databases. [Installer (windows)] - Fixed: Updating an UMS installation (4.09.x or older ) directly to versions between 5.09.100 and 6.02.100 (inclusive) did not work completely. In these cases the installer asked for the data directory (which already existed) and even if the user entered the same path as the UMS used before, the folder was completely overwritten. Additionally, if the UMS used an embedded database before the update, a manual reactivation was sometimes required after the update. ============================================================================= IGEL Universal Management Suite ============================================================================= Version 6.02.100 Release date: 2019-06-14 HTML version of this Readme is available at: https://kb.igel.com/ums/releasenotes ============================================================================= Supported environment: ============================================================================= UMS Server: Microsoft Windows Server 2008 (64 bit and with SP2) Microsoft Windows Server 2008 R2 (64 bit and with SP1) Microsoft Windows Server 2012 (64 bit) Microsoft Windows Server 2012 R2 (64 bit and with Update 2919355) Microsoft Windows Server 2016 (64 bit) Microsoft Windows Server 2019 (64 bit) Ubuntu 16.04 (64 bit) Ubuntu 18.04 (64 bit) Oracle Linux 7 (64 bit) Red Hat Enterprise Linux (RHEL) 7 (64 bit) UMS Client: Microsoft Windows 7 (64 bit and with SP1 ) Microsoft Windows 8.1 (64 bit and with Update 2919355) Microsoft Windows 10 (64 bit) Microsoft Windows Server 2008 (64 bit and with SP2) Microsoft Windows Server 2008 R2 (64 bit and with SP1) Microsoft Windows Server 2012 (64 bit) Microsoft Windows Server 2012 R2 (64 bit and with Update 2919355) Microsoft Windows Server 2016 (64 bit) Microsoft Windows Server 2019 (64 bit) Ubuntu 16.04 (64 bit) Ubuntu 18.04 (64 bit) Oracle Linux 7 (64 bit) Red Hat Enterprise Linux (RHEL) 7 (64 bit) Backend database (DBMS): Microsoft SQL Server 2012 Microsoft SQL Server 2014 (with Cluster Support) Microsoft SQL Server 2016 (with Cluster Support) Microsoft SQL Server 2017 (with Cluster Support) Oracle 11g R2 Oracle 12c PostgreSQL 9.4 - 9.6 and 10.1 Apache Derby 10 ============================================================================= Security Fixes: ============================================================================= [High Availability Feature] - Fixed: HA-Installation unnecessarily opened a debug port (ISN 2019-05) ============================================================================= New features: ============================================================================= [UMS common] - Changed: The administrative task "Assign objects to the devices of views" now provides the possibility to assign firmware customizations, files and firmware updates to the devices of views - Added: Disk Usage notification type for the UMS notification system. (Help → Notifications) - Added: Global notification type for the UMS notification system to inform the user of important news like maintenance times, bugfixes, etc. (Help → Notifications) - Changed: Tomcat access log files are now also collected as part of the support information (UMS Console -> Help -> Save Support Information) - Changed: The bundled Oracle JRE was replaced with Azul Zulu JRE 8 Update 212 - Updated: Apache Tomcat from version 8.5.37 to 8.5.40 [Console, common] - Added: Administrative tasks notification type for the UMS notification system (Help → Notifications) - Added: The UMS now displays all connected monitors of a device, previously it only displayed two - Changed: Notification pop up on start up is hidden if there are no notifications - Changed: In UMS Scan Devices dialog, when the Rescan actions is executed, the current filter is maintained and applied again to the new scan results (UMS -> Scan For Devices -> Scan -> Rescan) - Added: Functionality to assign objects (profiles, fwcs etc) to more than one device at once [Profiles] - Changed: Simplified dialog to create a new profile [Thin clients] - Changed: Redesigned 'Save device files for support' dialog and provided the possibility to save files of multiple devices and devices of views (Help -> Save device files for support) [AD / LDAP integration] - Added: LDAPS support for AD configuration [Mobile Device Management (MDM)] - Added: Public port and address are now part of the MDM enrolment codes [Views] - Added: New View criterion for device licenses [Automatic License Deployment (ALD)] - Changed: Default automatic distribution method of new packs (except for Workspace Edition packs) altered from 'Enabled' to 'Enabled (with conditions)' [Console, administration section] - Changed: The recipients to send a test mail to can now be configured (UMS Administration -> Mail Settings -> 'Send Test Mail') - Added: Wait dialog during ICG certificate creation to indicate progress (Global Configuration -> Cloud Gateway Options) - Added: Server and broker icons now show status - Updated: DSA-export graphic (Global Configuration -> Licenses -> Device's Licenses -> 'Export Unit ID list') - Changed: Renamed 'remove' buttons in the ICG configuration dialog to avoid misunderstanding (UMS Administration -> UMS Network -> Igel Cloud Gateway) - Added: Dialog to Naming Convention feature to guide the user (Global Configuration -> Device Network Settings -> Naming Convention) - Added: Option to create ICG wildcard certificates (UMS Console -> UMS Administration -> Cloud gateway options -> Create signed certificate) [IGEL Cloud Gateway (ICG)] - Added: New safeguard to the ICG certificate dialog to prevent inexperienced users from making mistakes (UMS Administration -> Global Configuration -> Cloud Gateway Options) - Added: Option for the certificate creation dialog whether new cert should be CA or End Entity - Added: Check to prevent users from signing a certificate with a non-ca certificate - Added: X509-Extensions to show certificate dialog [Server, common] - Changed: Suppress server identity in tomcat headers and by disabling default error pages - Updated: Microsoft SQL Driver to support TLS 1.2 in microsoft sql database connection - Changed: All tables of the database schema are optimized (Optimize Database) - Updated: EULA text [High Availability Feature] - Changed: Now support files also contain watchdog log files in "Save support information" function (UMS Console -> Help -> Save Support Information) ============================================================================= Resolved issues: ============================================================================= [UMS common] - Fixed: Resetting a device to factory defaults could lead to various errors (Device context menu -> Other commands -> Reset to Factory Defaults) - Fixed: Missing configuration state change flag for template value and value group assignments - Fixed: Text color of warning hints when some/none of the selected devices have Secure Terminal enabled - Fixed: W10 devices do now apply a new network name, if the configuration “Adjust network name if UMS-internal name has been changed” is set in the UMS and the device has been renamed (UMS Administration → Global configuration → Device Network Settings → Adjust Names of devices) - Removed: Unused icons [Console, common] - Fixed: Already existing archive of a profiles export could not be overridden - Fixed: UMS console login dialog was not properly focused - Fixed: Notifications can't be deactivated for users of an imported AD group - Fixed: Some Texts could not be read because the text and the background had the same color - Fixed: Error message when exporting result in SQL console (Misc -> SQL Console -> 'Save Result') - Fixed: Double click on indirect assigned objects redirects you to the Object and on right-click a pop-up window opens - Fixed: Selecting 'Don't show again' on a notification on the Notification Dialog had no affect (Help -> Notifications) - Fixed: Wrong color in move to recycle bin confirmation-dialog - Fixed: Issue where devices were erroneous shown as unlicensed - Fixed: Issue where the close-button sometimes was not visible on the update-check dialog (Help -> UMS Update Check) - Fixed: Devices imported from a CSV file with the IGEL Serial Number Format have an empty serial number (System -> Import -> Import Thin Clients) [Thin clients] - Changed: Wake up commands are not sent to devices when they are registered in UMS through ICG [Profiles] - Fixed: Re added missing file picker for field 'file name' on page 'System -> Update -> Snapshots -> Download'. File picker is now properly enabled after resetting the file name parameter with enabled template keys checkbox - Fixed: Changes of the screen rotation (rotating a screen with the arrow left/right buttons on the User Interface -> Display page) could not be saved in profiles - Fixed: Re added missing ftp password field in W7 profile configuration dialog. (System -> Snapshots -> Upload/Download) [Template keys and groups] - Fixed: Variable expressions in template keys are now supported for devices registered into directories [Firmware Customization] - Fixed: The FWC import did not upload the provided files. - Changed: The Firmware Customization import file is validated and the import process is aborted if the imported parameters are not supported by the current UMS version [Views] - Fixed: CSV-exports did not include the column headers of custom device attributes (Admintask: export view as...) - Fixed: Special characters from Eastern Europe aren't shown correctly within view exports (View context menu -> Save as) - Fixed: Reduced processing time of assignment/detachment of profiles to/from the devices of a view [Jobs] - Changed: By deleting a server in UMS Administration - UMS Network - Server, the assigned devices are assigned to another available server and the Job Execution data is deleted [Automatic License Deployment (ALD)] - Fixed: Empty error message is shown if configuration of UDC2 Deployment is changed and the configuration page is left without saving the changes - Fixed: Occasionally a product pack is shown twice in the registered packs section (UMS Administration -> Global Configuration -> Licenses -> Deployment) [Universal Firmware Update] - Fixed: A device directory can't be assigned to an Universal Firmware Update if the directory has already such an assignment - Changed: The progress bar shows the download process of Universal Firmware Update with a better accuracy [Configuration Dialog] - Fixed: Configuration dialog combobox "Multi monitor fullscreen mode" was missing in UMS 6 for clients with firmware 10.4.100 (configuration dialog page Sessions -> Citrix XenDesktop/XenApp -> HDX/ICA Global -> Window) [Console, administration section] - Fixed: The Certificate Management Node (UMS Administration-> Global Configuration -> Certificate Management) was only visible to the db-admin - Fixed: Issue where mutiple ICGs where shown in the wrong order (UMS Network -> Igel Cloud Gateway) - Fixed: In the TC Rich Message Editor the reject changes message does not appear anymore if you switch the template and the previous had no changes (Device context menu -> Other commands -> Send Message) - Fixed: UMS Licenses with more than one corresponding notification couldn't be deleted (UMS Administration -> Global Configuration -> Licenses -> UMS Licenses) [Console, web start] - Fixed: Webstart sometimes showed outdated splashscreen - Added: Expressive error and log messages when uploading files to UMS server fails due to invalid server host name [WebDAV] - Fixed: Webdav credentials weren't recognized under certain circumstances [IGEL Cloud Gateway (ICG)] - Fixed: UMS lost ICG connection, if a lot of devices were ICG administrated (device count> 500) - Changed: When a device is registered on ICG, ICG credentials are cached before device is removed from the Recycle Bin, and then stored again. Only applies for devices that are in the Recycle Bin at the moment of ICG registration [Server, common] - Fixed: Issue with not correctly identifying the operating system of Windows Server 2016/2019 (UMS Administration -> UMS Network -> Server -> UMS Server selected -> Attribute - Operating System) - Fixed: A valid Workspace Edition license/ Enterprise Management license was not recognized due to not properly formatted timestamps - Fixed: Bug in the device authentication [High Availability Feature] - Fixed: HA-Installation unnecessarily opened a debug port (ISN 2019-05) - Fixed: Communication issues within a HA-Network - Fixed: Update installation wizard contained misleading user prompt - Fixed: Commands for servers, load balancers and ICGs could create an unreadable balloon tip [Installer (linux)] - Fixed: Uninstaller on Linux can from now on only be executed with root privileges and shows the correct UMS version - Fixed: Splash screen was shown as "win0" on panel in GNOME desktop on RHEL7 and Oracle Linux 7 - Added check for running UMS Console in Linux installer - Fixed: UMS binaries (e.g. RemoteManager.bin) do not start on RHEL 7.x or Oracle Linux 7 due to ABI compatibility issue [UI / Look&Feel] - Fixed: Rich Message Templates could spill their colors into the UMS ============================================================================= ============================================================================= Including features from private builds of Version 6.01.100 ============================================================================= ============================================================================= IGEL Universal Management Suite ============================================================================= Version 6.01.130 Release date: 2019-04-23 ============================================================================= New features: ============================================================================= [Devices] - Added: Support for Migration firmware (OS10 to OS11) ============================================================================= Resolved issues: ============================================================================= [Console, common] - Fixed: An error occurred when exporting the result of a SQL query in the SQL console. (UMS Console -> Misc -> SQL Console) [Views] - Fixed: Replaced wrong UTF-16 encoding with UTF-8 encoding. (UMS Console -> View -> Export -> CSV file format) [Server, common] - Fixed: A bug in the UMS user authentication [Universal Firmware Update] - Fixed: A device directory cannot be assigned to an Universal Firmware Update, if the directory has already a Universal Firmware Update assignment [Automatic License Deployment (ALD)] - Fixed: Occasionally a product pack is shown twice in the registered packs section ============================================================================= IGEL Universal Management Suite ============================================================================= Version 6.01.120 Release date: 2019-03-28 ============================================================================= Resolved issues: ============================================================================= [IGEL Cloud Gateway (ICG)] - Fixed: UMS lost ICG connection, if a lot of devices were ICG administrated (device count> 500) ============================================================================= IGEL Universal Management Suite ============================================================================= Version 6.01.110 Release date: 2019-03-27 ============================================================================= Resolved issues: ============================================================================= [UMS common] - Fixed: Reset a device to factory defaults could lead to various errors [Console, common] - Fixed: Already existing archive of an profiles export cannot be overridden - Fixed: Login dialogue was not properly focused. - Fixed: Some texts could not be read, due to the text and the background had the same colour [Profiles] - Fixed: Re-added missing file picker for field 'file name' on page 'System -> Update -> Snapshots -> Download'. File picker is now properly enabled after resetting the file name parameter with enabled template keys checkbox - Fixed: Re-added missing ftp password field in W7 profile configuration dialogue. (System -> Snapshots -> Upload/Download) [Views] - Fixed: CSV-exports did not include the column headers of custom device attributes (Admintask: export view as...) - Fixed: Special characters from Eastern Europe are not shown correctly within view exports [Console, administration section] - Fixed: UMS Licenses with more than one corresponding notification could not be deleted [Console, web start] - Fixed: Webstart sometimes showed outdated splash screen [Server, common] - Fixed: A valid Workspace Edition license/ Enterprise Management license was not recognized due to not properly formatted timestamps - Fixed: Bug in the device authentication [Installer (linux)] - Fixed: UMS binaries (e.g. RemoteManager.bin) do not start on RHEL 7.x or Oracle Linux 7 due to ABI compatibility issue